Default CTC 169 OnScreenDisplay Problem

The ProScan 27" set with CTC 169 chassis is over ten years old.
Recently onscreen display started tearing; after an hour or so of
"warmup" it would be OK.
Now it never displays properly. Video modulation comes through.
Horizontal sync is the problem; vertical is OK.
I have the Field Service manual, which says "The OSD horizontal position
is phase-locked with the H-SYNC signal at Pin 23. . . . Components
external to the micro at Pins 25 and 26 set up the characteristics of
the OSD PLL."
Pins 25 and 26 go to 2 resistors and one cap to ground.
This set is a mess to work on. If I am sure that it's one of these
three parts, I'll do it. (Otherwise I'll just forget about the OSD!)

Any suggestions?

Thanks -