Jon Elson wrote:


Most other DVMs I've had would read accurately until the digits could no
longer be read, LONG after the low-bat indication was on. At least one
Fluke I had would start giving totally impossible readings as soon as the
low-bat indicator showed. I guess there was less margin on the voltage
reference.



** My rather old "Fluke 70 Series 2" displays the battery warning symbol at 6.4 volts - but still works fine to less than 5 volts.

The LCD display is good down to 2.5V but readings are are crazy.


...... Phil