Thread: Grid Dip Meter
View Single Post
  #3   Report Post  
Posted to sci.electronics.repair
Cursitor Doom[_4_] Cursitor Doom[_4_] is offline
external usenet poster
 
Posts: 2,783
Default Grid Dip Meter

On Sun, 29 Nov 2015 16:16:27 -0800, Jeff Liebermann wrote:

Sorry, no recommendations as all my stuff is ancient.


So's a lot of my stuff. But there's nothing wrong with old gear IMO it's
the quality of it and whether it's in calibration that counts. The only
issues with GDOs IME are that they're not too bad for the lower frequency
RF stuff, but hopeless for anything higher.