David Lesher wrote:

Deane Williams writes:


The motor still spins easily. There is no DC continuity from the power p=
lug but I beleive this is normal for induction motors? Perhaps the overheat=
sensor has opened permenently.


You got it. As they age the bearing dry and they pull more current.
Eventually they open the Microtemp protecter within....



** "The motor still spins easily" contradicts that idea.

Seen a few cheap Chinese fans with tight/stuck bearings - takes a fair bit of solvent to get them spinning again.

The OP has no so far bothered to open a fan a check the motor wiring for continuity.