Default High pressure or low pressure cylinder?

On 17/08/2015 22:07, wrote:
On Monday, 17 August 2015 21:36:39 UTC+1, Vir Campestris wrote:
We're having the whole lot stripped out - want one that isn't 30 years
old and badly insulated for the new boiler - and the installer has
suggested a mains pressure cylinder. Apart from anything else the
warranty is longer!
What do the team think?


Depends on your mains pressure and flow.

On the upside
- no loft tanks
- mains pressure hot water for showers

On the downside
- higher initial cost
- requires annual safety check
- requires tundisk and pressure relief pipework
- may also require pressure regulating valve and pressure relief valve on the cold mains inlet as well


What does the annual safety check entail?