View Single Post
  #2   Report Post  
AWM
 
Posts: n/a
Default Control of Central heating from PC - Thermostat Inputs - Relay outputs


"John" wrote in message
...
Dont ask why (I suspect i am over complicating matters somewhat) but I am
thinking about attempting to control the central heating via pc.

To do this I need to take two tempreature readings (flow and return) and
feed this information to the PC (the capacity for a third room thermostat
would be useful for later usage)

Outputs would need to control two relays which would switch the heating
accordinly.

As the processing is mostly mathematical, the easiest system to use (this

is
a prototype) would be something like Excel, rather than having to writing
dedicated software. Ideally, the imput readings would be displayed in a
cell, and outputs can be switched depending on the value in a second
calculated cell.

I am sure that this should not be difficult with the right hardware? Is it
more diffult that it sounds?

Are there any suitable low cost data input output boards that would help?
Any links?

A few ways you can do this Picot do printer port data loggers than can be
read directly into Excel spread sheets --- I've tried this and it works.
Howerver a better way of measuring temperature is using Dallals
semiconductor DS18S20 temperature sensor, a selection of software for
reading these is available off the net but you may find a combinatio of
Autom8it and Quasar electroics 3145 temperature logger the easiest and
cheapest to get working.
Links
http://www.picotech.com/data.html
http://autom8it.com/
http://quasarelectronics.com/computer_projects.htm