View Single Post
  #4   Report Post  
Posted to sci.electronics.repair
Michael Black[_2_] Michael Black[_2_] is offline
external usenet poster
 
Posts: 378
Default Searching for a good LCD display for a FLUKE 8010A DMM

On Wed, 4 Feb 2015, wrote:

I heard the "bleeding" LCDs were a problem with some Flukes. Might be
hasrd to get.

I wonder just how hard it would be to adapt it to another display. Those
did not have all that elaborate like a phone or a monitor. Each digit
gots eight wires.

Since you'll never find where Fluke bought them or had them made you
would have to deal with rewiring because the pinout is unlikely to be
the same. In that case, really you could adapt it to LED. You owuld have
to build a little buffer board because LEDs pull alot more current. But
then again, I find them easier to read.

I don't think so. The signals coming out of the DMM IC would be different
and they'd be multiplexing the signals differently.

I thought it was Fluke that used that Intersil famous DMM IC. SOmeone wsa
talking about that recently elsewhere something about Fluke (I think it
wsa) going to Intersil, and then Intersil released the IC as a new
product, or maybe a modified version.

If that's the case, Intersil released to versions of the basic DMM IC, one
to drive LEDs, the other to drive LCDs. One might look up the
datasheets (which likely are still available) to see the differences.

Michael

And beieve it or not, a friend of mine actually does have the part. The problem is tha tit is inside of a working meter. He might sell it but if you buy it, then you don't have to do anything, it works. I think he has another one but not sure of the model. That one could be made expendable because it has an offset problem. It had batteries and they leaked on the board so we beene cleaning it for the last few months. I forgot thre model so it might not fit anyway.

I'll email him if you want, see how much he wants for the one with the offset and get the model. It's too late to call right now.