On 10/22/2014 1:52 PM, Gareth Magennis wrote:
Following on from the Automotive Relay thread;
What are the reasons behind the apparent fact that relays last longest
in this order of coil protection:
Arcing on opening.
1. No protection at all
Fastest opening. Less damage to contacts.
2. Zener diode
If indeed your order is correct,
Slow opening.
3. Resistor (6 x coil resistance)
Slower Opening.
4. Diode
Slowest Opening.
Most damage to contacts.
(No protection being the relay lasts longest, the standard diode being
the worst thing for the relay - forget the circuit protection issues
just now)
From this data - scroll to the bottom for a chart:
http://www.te.com/commerce/DocumentD...=CS&DocLang=EN
Cheers,
Gareth.
---
This email is free from viruses and malware because avast! Antivirus protection is active.
http://www.avast.com