Thread
:
VFD Motor ringing
View Single Post
#
2
Posted to rec.crafts.metalworking
Lloyd E. Sponenburgh[_3_]
external usenet poster
Posts: 4,632
VFD Motor ringing
PCS fired this volley in news:76cc86cc-69e1-4697-
:
In general, what's up with a 3ph AC motor on a short cable ringing?
Does it ring at all speeds, or only when accelerating and decelerating?
I _don't_ have the PC3 manual, but if there's a setting for the chopping
frequency, that might change things. You might have just gotten lucky
and found a motor the windings of which resonate at exactly the chopping
rate of the VFD, as set up.
Although the put out a "sine wave" (sort of), there are steps in it that
can cause windings to ring.
Lloyd
Reply With Quote
Lloyd E. Sponenburgh[_3_]
View Public Profile
Find all posts by Lloyd E. Sponenburgh[_3_]