View Single Post
  #6   Report Post  
Posted to sci.electronics.repair
Gareth Magennis Gareth Magennis is offline
external usenet poster
 
Posts: 818
Default Line6 amp repair, Spider 111 30, 2006


"N_Cook" wrote in message
...
Replaced the worst 2 pots with fairly stable minimum few 100s of ohms
settings of the rest, no LEDs.
I'm now assuming the inbuilt flash memory of the
P89LPC936F is corrupted as distinct from the RAMs. There is a vacant
header for in-cct programming with RST on the overlay. This line goes to
the INV-RST pin of the uC and according to the datasheet a LOW on there
will reset the uC, but no change still no LEDs. It looks as though to
erase the flash , needs a Chip Erase command via in-cct programming, so
that looks like the end of this usual digital farting about. One more
effort ,Cannot find "factory reset" for Line6 spider stuff, will try 5
seconds on each at power-up and then 2/3/4 of the adjascent ones.




Hold Clean channel button and power on.

User manual he
http://l6c.scdn.line6.net/data/6/0a0...ev%20A%20).pdf



Gareth.