View Single Post
  #5   Report Post  
Andrew Gabriel
 
Posts: n/a
Default Earth and new light fitting

In article ,
"Novice DIY'er" writes:
Am 75% through a kitchen re-build. Now, the lurverly new halogen lights
we've bought from B&Q need to be fiited. Removed old fitting to see what I
assumed was the normal two wires (black and red). Fine, open box for shiney
new light fitting and 'SH*T', it's got an earth wire as well! Hmmm, who
nicked my earth cable in the attic? Had a wee peak behind the light switch
and ITS got an earth but none coming down from the attic! So, do I need to
crawl about in the attic to try and trace the wires back, add an extra earth
wire and strap it to a pipe, see where the light switch wire goes to and
connect it to that, set up the camping bed in the garage again?


If you're lucky, you can just trim the cable back a bit more
and find someone cut the earth short. If your lighting circuit
isn't earthed, then you will need to take the lamp back to
B&Q and choose a double insulated one which doesn't need
earthing, and also note that you need to get your lighting
circuit rewired at some time (or rewire it first). You don't
"strap it to a pipe".

You should also verify the earth is actually connected at the
other end.

--
Andrew Gabriel