View Single Post
  #5   Report Post  
Posted to sci.electronics.repair
Cydrome Leader Cydrome Leader is offline
external usenet poster
 
Posts: 1,910
Default Find Small AC motor Fusable Link?

Paul Drahn wrote:
On 8/20/2013 10:39 AM, KenO wrote:
Have a 16" Chinese AC Electric Fan that has a blown motor due to lack of lub.

Did some quick checking and the motor blew before doing unrepairable damage to the bushings.

Have never had a blown Chinese AC Electric Motor before so would be interested in any tips finding the blown fusable link.

Did some forum searching but found nothing using AC electric motor fusable link but found nothing.

Thanks

Ken

You will find it hidden in the motor field windings. These are not
repairable. Similar to letting the magic smoke out and being unable to
get it back in the component.

Paul


I just had a crappy Lakewood 20" box fan burn out. I've been oiling the
bearings for years to keep the junker running, but today it just died
while I was sitting a few feet away.

It turns out there's slim thermal fuse hidden in the vinyl tubing where
the leads for power/speed and the run cap are attached to the windings.

It would be a 10 minute repair, if I had any spare 115C 2amp thermal
fuses.

Taking into account that the newer version of window fans are even
junkier, it may be worth the $5 to get a hong kong post 10 pack of ebay
thermal fuses and hope at least one works.

It is quite possible some of these cheapo fan motors can be fixed, or at
least tricked back into sort of working.

The motor in my case wasn't even varnish dipped. You can dig straight into
the windings with a spudging tool.