Default power supply design question

On Sunday, August 4, 2013 10:07:50 AM UTC-4, wrote:
Perhaps this isn't the forum for this but I thought I'd try. I have three Norelco electric shavers. Two are rechargeable types with built in chargers, and each having two 1.20 volt nicads. I've replaced the batteries in both of these portable units several times over the years and now it seems like neither one will charge it's batteries anymore.



The third one uses the same 2.4 volt motor but it runs off 120VAC. That one has a bad power supply as well. I have tried to repair these shavers but I think the problem on each one is in the hybrid circuit and/or other proprietory parts. And since these are quite old I'm pretty certain that no parts would be available.



So I have built and am currently bench testing a .050 A. constant current source using an LM317T, (please refer to the link below). I set the charge current for .050A with a 22 ohm resistor, and it works quite well with a supply of 12V +/- 50 %. And as a bonus at this setting the chip does not require a heat sink.This test setup is currently charging two .600AH AA NMIH batteries. I plan on eliminating everything but the motor in each shaver, installing two batteries, a small switch, and building a small breadboard version of this 50ma. constant current charger to use with each shaver. I have been charging my AA nicad's and NMIH's off my adjustable current bench power supplies like this for years without ever having any problems. I can remember to take them off charge after 14 hours or so.



So in theory using this arrangement, charging the shaver's batteries directly from an automobile cigarette lighter jack would work fine. And I can easily make that an option, however I would prefer to have the shaver work with the supplied coil cord as originally intended, and that is from 120VAC. One reason being (and perhaps it sounds petty) but it would be nice to be able to keep both the coil cord and shaver in their small zippered case and not have to add, (and bring) an external primary supply with me everywhere the shaver goes.



Now I'm sure that I can figure a way to drop the AC line down to a safe operating level and then (hot), rectify and filter the DC to run the IC. And perhaps Norelco was doing this in each shaver, and as far as I can tell without power line isolation, I would not feel comfortable with that arrangement.



So now to complete the project in a technically correct way, I need to come up with a simple miniature isolated primary supply that will provide around 12.0 volts of filtered DC. and one that I can build into the shavers. I'm hoping that the old guts that I stripped out of each shaver will afford me that room. A 12 volt transformer would be the most simple way to accomplish what I'm trying to do, but I don't think I've ever seen one small enough to fit inside one of these shavers. I have enough room for something that would measure about a one inch cube.



So, this probably sounds like a stupid question, but I have to ask. Does a 120V 60HZ transformer this small even exist? This primary supply would not even have to be regulated and the current requirements are miniscule.. I'm not experienced enough to try to design a switcher for this application. I would just like to keep this real simple if possible. Of course if I had a bit more real estate to work with this would be a non issue. Thanks for any assistance. Lenny



I 'm kind of liking the beard but the old lady is getting tired of it.



http://www.hobby-circuits.com/circui...attery-charger


William
I was just joking man. It's not confrontational or anything like that. We both respect each others feelings. It was really nothing more than good natured ragging. But tell me more about this breast binding. That sounds like something I might be interested in. Lenny