Default Ashdown MAG 300 amp, 2004

Both 6.3amp fuses blown, 2 diodes of the bridge rectifier s/c. Internal
failure of this bridge, dodgey looking splodge logo, presumably Fronter
logo and 8amp rating, marked
AC BP8-04
or something else to change as well?
Main caps look ok and ESR (for what its worth in such cases) ok
The 2 failed diodes are
-ve to AC
+ve to other AC
Suspiciously 2 solder points look like crazed PbF solder but all is SnPb,
melted and reformed? the 2 points are at the -ve terminal and the AC
terminal of the other failed diode. Output devices DVM-D cold test as
expected. No heated traces or even obvious gaseous eruptions from the
bridge or anything out of the normal. No reported preceeding noises
prior to failure.