DC motor troubleshooting
"Artemus" fired this volley in news:kmmj0j$8a5$1
@dont-email.me:
Sounds like one of the flex wires connecting the carbon part of the
brush
to the brush holder is open. Or the connection between A1 or A2 and
the
brush holder is open.
Art
Yup.
There's not much can go wrong there, Ig. Check the voltage between the
inlet terminal for A1 or A2 and its corresponding brush holder.
If there's anything more than a nuisance couple of volts, you've got a
break between the A1 or A2 terminal and its corresponding brush.
LLoyd
|