View Single Post
  #3   Report Post  
Posted to rec.crafts.metalworking
Lloyd E. Sponenburgh[_3_] Lloyd E. Sponenburgh[_3_] is offline
external usenet poster
 
Posts: 4,632
Default DC motor troubleshooting

"Artemus" fired this volley in news:kmmj0j$8a5$1
@dont-email.me:

Sounds like one of the flex wires connecting the carbon part of the

brush
to the brush holder is open. Or the connection between A1 or A2 and

the
brush holder is open.
Art


Yup.

There's not much can go wrong there, Ig. Check the voltage between the
inlet terminal for A1 or A2 and its corresponding brush holder.

If there's anything more than a nuisance couple of volts, you've got a
break between the A1 or A2 terminal and its corresponding brush.


LLoyd