Rigid Conduit vs Regular Iron pipe
On Sat, 02 Mar 2013 15:08:28 -0500,
wrote:
On Sat, 02 Mar 2013 03:36:14 -0800, Gunner
wrote:
On Fri, 1 Mar 2013 15:40:45 -0800 (PST), "
wrote:
On Mar 1, 4:11*pm, Pilgrim wrote:
Can any one tell me what the difference between rigid conduit and iron
pipe? inner finish threads on the pipe and in the fittings and any other
significant differences.
TIA
CP
You can bend conduit with an inexpensive tool. Conduit is much
lighter and cheaper than pipe.
Dan
Conduit is thin wall material. It cant be threaded with any
suitability. Its not designed to carry anything other than wire.
You are thinking EMT - electro-metalic tubing - not Rigid Conduit.
You are absolutely correct. I glossed over the first "rigid"
My appologies indeed.
A definate Brain Fart on my part.
Gunner
Rigid conduit is thick, and is threaded for EVERY use.
1" rigid conduit is .126 inch wall. The thread is generally a straight
thread instead of a tapered thread on pipe.
1 inch Sched 40 iron pipe is .130" wall thickness.
2 inch rigid is .146 inch wall thickness, while sched 40 iron is .150
nominal thickness
Rigid steel conduit can be galvanized (in and out) electro galvanised
(outer only) with organic coated interior, or organic coated in and
out - and Rigid conduit can also be aluminum or stainless steel or red
brass.
RMC has a smoother interior than pipe - it is a rolled, electrically
welded seam tubing with uniform wall thickness and a defect free
interior surface - required for pulling wire.
Black Iron Pipe is made from ductile iron - not steel (generally
speaking).
Pipe is thick wall and is designed to be threaded and then threaded
into pipe fixtures...
Its capable of carrying significant pressures
Gunner
The methodology of the left has always been:
1. Lie
2. Repeat the lie as many times as possible
3. Have as many people repeat the lie as often as possible
4. Eventually, the uninformed believe the lie
5. The lie will then be made into some form oflaw
6. Then everyone must conform to the lie
The methodology of the left has always been:
1. Lie
2. Repeat the lie as many times as possible
3. Have as many people repeat the lie as often as possible
4. Eventually, the uninformed believe the lie
5. The lie will then be made into some form oflaw
6. Then everyone must conform to the lie
Reply With Quote
Gunner[_7_]
View Public Profile
Find all posts by Gunner[_7_]