View Single Post
  #26   Report Post  
Posted to sci.electronics.repair
Phil Allison[_2_] Phil Allison[_2_] is offline
external usenet poster
 
Posts: 1,716
Default Power supply question


"klem kedidelhopper"

If you have done this and gotten 36 volts, then you actually have a
48V transformer with CT

Jamie


What you're referring to is a 12VCT transformer. Connecting either a
bridge and not using a center tap or just two diodes across the full
secondary with cathodes tied together using CT as common connected to
an output filter will yield 18VDC.


** ****ing BULL **** !!!!!!!!!!!!!!


I've tried it and it does



** Then explain how every other person on the planet get a different result
??

Using a CT as common halves the voltage from the tranny and so halves the DC
voltage as well.

My god you are ****ing stupid.



..... Phil