Default Tek 465 trigger problem.

On Fri, 18 Jan 2013 16:36:30 -0500, "tm"
wrote:


"John Fields" wrote in message
.. .
Hello,

I have a Tektronix 465 which is perfect in every way except that the
horizontal trigger has gone belly up and the trace free-runs no matter
what.

Clue, please?

Thanks,

--
JF



Bad tunnel diode?

Do you have the service manual?

http://bama.edebris.com/manuals/tek/465(2)/


---
Yes
---

Can you trigger the B sweep?


---
Yes.

--
JF