View Single Post
  #5   Report Post  
Posted to uk.d-i-y
Jonathan Jonathan is offline
external usenet poster
 
Posts: 643
Default Not sure how to describe it but . . .

On Jan 17, 4:14*pm, Nightjar
wrote:
On 17/01/2013 15:46, Jonathan wrote:









On Jan 17, 3:43 pm, Nightjar
wrote:
On 17/01/2013 15:20, Jonathan wrote:


I want to try to make some flood gates for our doors and they are very
expensive to buy. I want to use some sort of fixing that I can screw
into the wooden door frames permanently. These would have a thread in
the centre that I could use to bolt through, I imagine, external
plywood to create a tight fit as needed.


I have never seen anything like that, apart from rawlbolts which are
not designed for wood so far as I know. Does anyone know of such a
thing, or have a better suggestion? Many thanks.


I used aluminium square U channel, bolted to the side walls either side
of the doorway, with a hole from front to rear, near the top. Matching
holes in the flood board allowed me quickly to drop the board (cut from
an old scaffolding board) into the channels and hold it in place with
metal pegs. I used rubber seals along the bottom and sides of the board
to make it reasonably water tight. That produced a quick to deploy first
line of defence, which could be backed up with sand bags behind the
board as time permitted.


As floods can happen at night, when most of us are asleep, I also fitted
a float switch outside, linked to an under dome bell, in order to give
enough warning to get up and put the boards in place.


Colin Bignell


I don't have enough depth of brick to attach the channels to,
otherwise sounds great. We get about four hours warning from the
environment agency.


Jonathan


We did have 18" thick stone walls. Back when I did that, flood warnings
depended upon the Police coming around with a loudspeaker vehicle and
they didn't always have enough warning to get to everybody.

BTW don't forget that, in most properties, water can get under the floor
through air bricks, so they need protection too.

Colin Bignell


I don't have air bricks but I do have a ground floor shower that water
might come through the drain. I haven't yet found the thing to block
that. Any ideas.

Jonathan