"Jim Thompson" wrote in
message ...
On Fri, 28 Sep 2012 21:57:20 -0500, legg wrote:
On Thu, 27 Sep 2012 12:44:00 -0700, Jim Thompson
wrote:
AC Cap Dropper DC Power Supply
Anyone know of a clever way to regulate other than the typical
brute-force zener clamp?
...Jim Thompson
Power level? Input range?
RL
0.8W, Input is 220VAC/50Hz full-wave-rectified.
...Jim Thompson
--
| James E.Thompson, CTO | mens |
| Analog Innovations, Inc. | et |
| Analog/Mixed-Signal ASIC's and Discrete Systems | manus |
| Phoenix, Arizona 85048 Skype: Contacts Only | |
| Voice480)460-2350 Fax: Available upon request | Brass Rat |
| E-mail Icon at http://www.analog-innovations.com | 1962 |
I love to cook with wine. Sometimes I even put it in the food.
The capacitor must go between the AC line and input to the bridge. It uses
the reactance of the capacitor as a dropping resistor.