On Tue, 19 Jun 2012 11:59:48 +0100 "N_Cook" wrote in
Message id: :

Anyone know of pics of the interior?

A previous "repairer" removed all fuses , ratings on overlay , so ok. But
did not mark the ribbons before removing all of them. Majority are mateable
without ambiguity. There are 2x 16 way ribbons with exactly the same IDC
connectors that could go to either of 2 places on the central board holding
the graphic sliders and LED bargraphs.
Completely different lengths to the ribbons , does not help to decide as the
headers are adjascent
One ribbon is from Conn1 of rear INSert sockets
The other from the CCD display board
Cannot start rectifying whatever the underlying problem was, before sorting
out this added problem


How about finding GND points on all three boards and using an ohm meter?