On May 21, 7:22*pm, Lawrence Borne wrote:
I have the standard modular ice maker for my amana fridge. *A few
months ago the ice cubes started getting smaller and smaller and
finally it just stopped making ice all together. *I tested all the
points with a meter and all seemed fine. *Everything works except it
does not fill with water. *I checked the fill tube for blockage and
the solenoid. *Here is the kicker. *If I short test points L and V the
solenoid activates and the ice tray fills. Then it freezes and dumps
the ice. *Except again, at the 11 O'clock position, no water. *So I
figured I had a bad thermostat and went ahead and bought an entire new
ice maker. *Installed it and I have the exact same problem. *With the
new maker I can fill the tray manually by shorting L&V for 7 seconds
which fills the tray. *Any ideas? *TIA.


L&V are standard points on all modular ice makers. They energize the
solenoid valve. Figuring it was the solenoid, I ordered one of those
too. However, the fact that water was coming out when energized made
me think there was no problem. I replaced the solenoid just now and
will see if that fixes it. Can't be anything else. The fact that the
ice got smaller and smaller means it is probably a solenoid that is
getting clogged or leaking water and allowing the fill tube to clog.