View Single Post
  #2   Report Post  
Posted to sci.electronics.repair,alt.home.repair
Tony Hwang Tony Hwang is offline
external usenet poster
 
Posts: 6,586
Default Do thermal fuses fail from old age?



jeff_wisnia wrote:
Over the years I've had a few thermal fuses in houshold appliances go
open for no apparent reason. When I've replaced them with ones with the
same temperature rating they stayed working fine for years more.

A couple of days ago our three year old Bunn coffee maker quit, because
a 141 degree celcius overtemperature thermal fuse on the water tank
opened. It might possibly have happened because the water tank
thermostat stuck closed, but after I repaired it the thermostat cycled
just as it should.

I was suprised to find that there were TWO identical thermal fuses
connected in series located right next to each other, the bodies were
actually touching. That seemed like a belt and suspenders approach,
unless there's a significant likelihood that a thermal fuse won't open
when it should?

Comments?

Thanks guys,

Jeff

Hi,
I understand they work on bi-metal strips. They can fail from fatigue.
Won't reset when temperature goes down cooling off.