Isolation transformer draws excessive current under no load condition
"spamtrap1888"
"Phil Allison"
I'd say your transformer is bad or somehow connected wrong.
** No way.
The OP's data shows it is operating normally and correctly.
10 degrees temp rise and a PF of 0.15 is A-OK.
Why doesn't the transformer data sheet include idle current, power
factor, etc.?
** Why should it ?
They are easily measured parameters and of little interest to most users.
If the safety ratings, VA rating, temp rise, dimensions, weight and mounting
details are all described - that is enough.
.... Phil
|