On Dec 26, 5:34*pm, PeterC wrote:
I've a light fitting to wire in that has just L and N - no Earth.
The 1-way, 1-gang switch is in a convenient position (! - had to happen
eventually) but there's no neutral.
I'll replace the switch with a 2-way 2-gang plate and wire the new light
into that.
Would it be OK to replace the switch cable from the existing ceiling rose
with flat 3 & E and use one of the wires as N, suitably marked of course?
--
Peter.
The gods will stay away
whilst religions hold sway


Or if it's easier, just run an extra single blue (6181y double
insulated)
http://www.meteorelectrical.com/cabl...00m-coils.html

You could run it via the light switch, or just directly to the new
light fitting.