On Fri, 11 Mar 2011 07:23:45 -0600, John Fields
wrote:
On Thu, 10 Mar 2011 19:05:51 -0700, Jim Thompson
wrote:
I need a 10 SECOND pulse stretcher!
I vaguely recall doing that using a counter, but can't recall the
details.
...Jim Thompson
n
____|____
/ \
| . . . |
+-+-------+-+
CLK---------------| |
+----+ | DIV n |
IN------|S Q|-+--|E TC|-+
| | | +-----------+ |
+-|R | | |
| +----+ +---OUT |
+-------------------------+
---
JF
Thanks, John F !!!
I knew it was simple. I was just having a brain freeze :-)
...Jim Thompson
--
| James E.Thompson, CTO | mens |
| Analog Innovations, Inc. | et |
| Analog/Mixed-Signal ASIC's and Discrete Systems | manus |
| Phoenix, Arizona 85048 Skype: Contacts Only | |
| Voice
480)460-2350 Fax: Available upon request | Brass Rat |
| E-mail Icon at
http://www.analog-innovations.com | 1962 |
Remember: Once you go over the hill, you pick up speed