On Fri, 11 Mar 2011 07:23:45 -0600, John Fields
wrote:

On Thu, 10 Mar 2011 19:05:51 -0700, Jim Thompson
wrote:

I need a 10 SECOND pulse stretcher!

I vaguely recall doing that using a counter, but can't recall the
details.

...Jim Thompson

n
____|____
/ \
| . . . |
+-+-------+-+
CLK---------------| |
+----+ | DIV n |
IN------|S Q|-+--|E TC|-+
| | | +-----------+ |
+-|R | | |
| +----+ +---OUT |
+-------------------------+

---
JF


Thanks, John F !!!

I knew it was simple. I was just having a brain freeze :-)

...Jim Thompson
--