LH Research Power Supply Mighty Mite
On Wed, 24 Aug 2011 11:11:26 -0400, Archon
put finger to keyboard and composed:
I don't think I'm going to get far by trial and
error. LH research seems to be Pioneer Magnetics, a completely useless
website with a very high opinion of themselves and no tech
support/documentation at all.
JC
You could determine which pins are the sense lines by measuring their
resistance (~100 ohms ?) to each of the +5V and Ground outputs.
The on/off pin would probably be sitting at Vstandby (+24V ?)
The AC Power Fail pin may identify itself if you rejumper your AC
input plug for 240VAC, assuming your local supply is 110VAC.
- Franc Zabkar
--
Please remove one 'i' from my address when replying by email.
|