View Single Post
  #5   Report Post  
Posted to sci.electronics.repair
Phil Allison[_2_] Phil Allison[_2_] is offline
external usenet poster
 
Posts: 1,716
Default online calculator or formula applicable to gauge less than 50 SWG ?


"Nutcase Kook"

All online and my tables stop at 50 SWG. I don't know if the standard
copper
resistivity formula breaks down over/less than 50 SWG. Wire in question ,
measured optically to about 0.05 mm diameter as too fine to mike up. About
19.7 ohm per metre but what is that in AWG or SWG ?


** Last time I dealt with fine enamelled wire like, that it was from the
high impedance (output end ) transducer of an Accutronics reverb unit.

But the finest I have seen is on the coil of an AKG D19 ( 200 ohms) mic
capsule - about 0.03 mm.

The D19 diaphragm was sold as a spare part and used in other mics, like the
original D12.



...... Phil