Steven Campbell wrote:
I understand the reasons for the expansion gap in a floating floor but is
10mm all round not a bit excessive? Can the floor really expand up to 20mm
in all directions?


yes. But in general it doesn't,


Reason I'm asking, I'm in the process of laying a floor and have left the
10mm round the perimeter of the room (as I removed the skirting and can
easily hide the gap) but am now up against the breakfast bar and am not too
keen on a big gap and don't want to put skirting round it.

Also due to bad planning I've been left with a small (20mm) L section of
laminate to fit which only leaves a few mm expansion. There is no way I can
cut it smaller to leave the proper 10mm gap.


Lets put it this way. I laid mine in spring over a total of 12x6 meters
with a large cutout for a central chimney and hall. So a sort of U
shaped piece.

I left about 4-6mm in most places but some was cut tight to the wall in
doorway recesses.

Come summer, it was lifting all over the place.. I had to relieve it by
4-6mm at one place.

The expansion was mainly across the grain of the boards - these were
Kahrs interlocking oak laminate engineering boards.

I would say total movement along the boards - across the 6m depth of the
tow combined rooms and passage - was about 4mm total.

It was more like 10mm or more over the 12m cross grain bits

Now 1% summer to winter along any grain is to be expected. IN fact I am
seeing 0.1%. So I can only conclude that the sheer weight of furniture
etc etc is keeping it all flat, and the stress is taken up in the wood
itself.


If you work on 1% you will be quids in. 0.1% is pushing your luck.
Possibly the best thing is to store it OUTSIDE under cover for a few
weeks - where typical RH will approximate to humid thundery no central
heating type conditions - and then lay it. It will shrink in winter,
with CH, but at least you will be as tight as it can be got.

If it does lift, all is not lost. I had the chippies in for something
else, and they used a reciprocating saw to trim a few mm off where the
whole lot was under huge stress. .

You don't say what size this floor is, but come back and tell me what
0.1% of the dimensions are, in terms of all round gaps



Cheers

Steven.