View Single Post
  #3   Report Post  
Posted to sci.electronics.repair
Stephen[_13_] Stephen[_13_] is offline
external usenet poster
 
Posts: 50
Default Hi, WOuld some kind soul help me diagnose my switch mode power supplies?

Would this be with the ribbon cable disconnected between the main board and
the PSU board?

If so which end should I measure?

"Uffe Bærentsen" wrote in message
k...

"Stephen" skrev i en meddelelse
o.uk...

Probing for grounds and voltages gives me on both units:

Pin number Good unit 2 Bad Units
pin 1 ground ground (this has zero
resistance to the metal case)
pin 2 ground ground (this has zero
resistance to the metal case)
pin 3 -3.42v 0.4v
pin 4 0v 12.85v
pin 5 8.73v 0.76v
pin 6 18.32v 7.4v
pin 7 0v 8.8v
pin 8 0v 8.5v


What is these resistances:
pin 1 to pin 2
pin 1 to pin 4
pin 1 to pin 7
pin 1 to pin 8

I think you have an issue with the ground/0V.



--
Uffe Bærentsen