View Single Post
  #32   Report Post  
Posted to uk.d-i-y
Tabby Tabby is offline
external usenet poster
 
Posts: 1,532
Default cleaning scratchy [electronics] pots / switches

On Mar 20, 11:37*am, Terry Casey wrote:
In message
on Sat, 19 Mar 2011 10:07:28 -0700 (PDT)
*Tabby wrote:



When the wiper connection goes o/c, you often get a dc offset showing
up on the output wire, creating major noise. Adding a resistor
prevents this, and can turn a very noisy pot into a silent well
behaved one, some of the time.


"When the wiper connection goes o/c ..." the pot no longer works, noise or no
noise, so replace the bloody thing!


Not at all, its common for pots to go momentarily o/c while rotating
them, and as long as its very brief its not normally noticed. If it
gets to the point where it is noticeable, then yes, its replacement
time.


NT