View Single Post
  #4   Report Post  
Posted to sci.electronics.repair
Bob Villa Bob Villa is offline
external usenet poster
 
Posts: 680
Default How-To: Common Cause Of Flat Panel PS Failure

On Mar 6, 3:31*pm, wrote:
On Sun, 6 Mar 2011 10:52:54 -0800 (PST), wrote:
On Mar 6, 7:35 am, Bob Villa wrote:
This is common to almost all flat panel power supplies. There are 4
electrolytic capacitors (same physical size) on the switching PS.
There are 2) 1000uF X 10V and 2) 470uF X 15V that usually bulge and/or
fail. You shouldn't pay more than .25to .50c for each. (I used higher
voltage on the replacements of 1000x15 and 470x25)
Symptoms of failure a slow power-up or totally dead.


Look for highest ripple current rating. Nichicon HZ, HN, Panasonic FM


G


Correct. *'Bob Villa' apparently wants repeat business as his high ESR
caps will fail quickly. *Note, 'Bob', good quality low ESR caps aren't
real expensive - you just aren't going to buy them at Radio Shack or
Caps R Us.

PlainBill


Got them from Newark (Illinois Cap. and Rubycon)