On Sun, 6 Mar 2011 10:52:54 -0800 (PST),
wrote:
On Mar 6, 7:35*am, Bob Villa wrote:
This is common to almost all flat panel power supplies. There are 4
electrolytic capacitors (same physical size) on the switching PS.
There are 2) 1000uF X 10V and 2) 470uF X 15V that usually bulge and/or
fail. You shouldn't pay more than .25to .50c for each. (I used higher
voltage on the replacements of 1000x15 and 470x25)
Symptoms of failure a slow power-up or totally dead.
Look for highest ripple current rating. Nichicon HZ, HN, Panasonic FM
G²
Correct. 'Bob Villa' apparently wants repeat business as his high ESR
caps will fail quickly. Note, 'Bob', good quality low ESR caps aren't
real expensive - you just aren't going to buy them at Radio Shack or
Caps R Us.