View Single Post
  #37   Report Post  
Posted to sci.electronics.repair
Phil Allison[_2_] Phil Allison[_2_] is offline
external usenet poster
 
Posts: 1,716
Default ESR meter built in seconds


"William Sommerwerck"

In other words... If the driving frequency is high enough that the
capacitive reactance is essentially zero, then the net impedance is
essentially the ESR. Right?


** Errr - yep.

But it ain't that simple.

One has to examine the actual impedance curves for typical electros to see
what the game is - the curve is like no other kind of cap.

Think of Q factors of circa 0.05 and ESRs that way exceed the calculated
impedance at 100kHz.



...... Phil