On Jan 23, 5:20*pm, "Rick Hughes"
wrote:
I posted back last year Q about using Acrylic sheet - advised that
Polycarbonate would be better *... went off intending to do job with triple
wall (or X-Lite) problem is you should fix this with ribs running vertical
... and in this instance due to width being ~80"
Can't get pieces ~80" wide and only 24" long ... (unless with very expensive
waste)

I'll describe job again ... anybody any thoughts ... would solid Polycarb
sheet work ... if so how thick over this span ?

Need some ideas on how to achieve fitting an acrylic sheet.
I have a large 'barn style' outbuilding, on 1 side it consists of 6 " square
post & gallows brackets.
The other side of this building is a fence, which comes up over 2/3 of the
open bays.
The bays are open to allow through draught of air, and air come through
fence no problem, the issue is the top 1/3rd allows rain to blow in, and too
much..

Hopefully this sketch will show what I mean:http://tinyurl.com/28q5u7g

I don't want to close off the bays as *I need air flow (& light) ... thought
about putting in a Polycarbonate sheet between the gallows brackets, just to
prevent the blow in of rain.
If I sloped this so that the lower edge was clear of upright posts, it
should also provide a 'drip' to prevent much of the *water ingress.
i.e. as in sketch *.. *aprox 10degreehttp://tinyurl.com/24jt8r5
Space between each support posts is ~80"' *... and there 3 bays to do.

Assume I use something like 10mm thick sheet work ?... I can easily
manufacture side & top edge supports out of wood .... *some ½" x ½" either
side of ends & top, would provide location slot.
The issue is what to use for bottom support ... i.e. along bottom edge.
80"' is a long span ... what I need is something waterproof I can bond to
sheet to provide a drip, and if it is longer than sheet would also provide a
fixing point to outer face of posts.

I have thought about using 16mm triple wall (or X-Lite) *in wrong direction
... i.e. ribs running left to right ... not sure if this is good idea or
not.
It would be a lot lighter than solid sheet.

Any suggestions.


Surely any sort of rigid bar along the bottom of the poly would do,
metal or timber. I dont see it mattering which way round the poly ribs
run in this case. I'm also not seeing why you'd pay the extra for
twinwall polycarb for an open structure, solid acrylic would do fine.
The main advantage of twin & triple wall is insulation.


NT