Still checking out humidifiers, even though I can only use one model,
not this one, and I notice that the poplular Aprilaire 700A has these
specs?
Water Feed Rate * * * * * * 6 Gallons/Hour
Water Capacity * * *18 Gallons/Day
If it feeds 6 gallons and hour, how come it only uses 18 gallons a
day?? *Where does it feed it?
It also says, "Complementing any HVAC system, the 700A has an
evaporation capacity of 0.75 gallons per hour, among the highest
capacity humidifiers sold." *So if its evaporation cap is 0.75 gph,
what does it mean that its WFR is 6 gph?
The water feeds though your supply, then trickles down over a water
pad. [looks like a filter] * * *Much of it is then drained out. * *
The 18gal/day is the .75 gal/hr x24. * * In reality, you're in big
trouble if it actually put that much into the air because it would
mean your furnace fan was running 24hours straight.
Thanks. I get it now.
http://www.alpinehomeair.com/viewpro...ctID=453058469
I bought one because folks here thought it was good. * *A couple years
later I replaced my furnace and bought another one because it was
*everything* it was cracked up to be.
Somebody will make a liar out of me-- but I can't remember seeing a
single naysayer on the Aprilaires.
Yes, when it was discussed last it sounded wonderful and I decided to
get one with my upcoming new furnace. With the curved lines in the
picture, I didn't realize how thick it was (more than 10 inches), and
I've only seen one of my neighbors' new furnaces, but it was arranged
just like the old ones are, and even though my basement ceiling is 8
feet like everyone else, somehow there is no place to mount the
Aprilaire or any of the fancy humidifiers. The flue is in the way
in the front, and the A-coil is in the way for more than a foot above
the 56" high furnace (the replacement might be 2 inches shorter, and
after that, I have to go look again where the other 28 inches go,
(Well, they duct goes at an angle, to avoid the I-beam that is above
the furnace, and that section is not tall enough for a fancy
humidifier.)
Anyhow, I'm stuck using a General Aire 800, which sticks out only an
inch, but is very simple, more than I want. (the only way to control
the amount of water is to change the number of fiberglass plates, and
it has a limit of 1.4 gallons a day, but that's okay for me.) Other
than that, it's a simple good humidifier and will fit almost anywhere,
and costs 61 dollars plus 9 dollars shipping at www.alpinehomeair.com
..
Jim
Agree with Jim on all of the above. Another way to look at it is if
it ran 24/7,
you'd put 18gallons of water into the air and it was use a total of
24X6
gallons, with the difference flowing through it and out the drain.
I never understood that they had a drain, and by coincidence not until
last night did I realize that the hole in the bottom of mine is meant
to be a drain sometimes. I thought it was just if things went wrong.
So I had water draining out of my humidifier for years, and didnt'
really know it, and that's why my furnace looks like crap, rust and
crud on and near the burner, adn why the flue-catcher or flue-funnel
rusted out at the start of last year, and why water poured out a
couple days ago and kept the furnace from running at all. I'm going
to take the drain hole and connect a hose to it to run the water away
from this furnace and certainly away from the next one, which I don't
want to look like crap.
(I have a spare burner I save for parts, that I got when a neighbor
got a new furnace, and it looks real nice after about 29 years when I
got it. But mine looks like crud, although that doesn't make it work
bad (other things make it break sometimes.).)
Actually
I'm surprised the ratio is that high. It needs to have some water
running
out so that it flushes the minerals out, which would otherwise
accumulate
on the media. But it seems on the high side to me.
My understanding is that they no longer make the 700A and it's
replaced
by the 700, which is basicly the same thing. They used to offer it as
a
700 without the outside temp control, and the A version with. Now the
700 includes it, AFAIK.
Maybe everyone was buying the 700A. I thought it was worth the extra
money.
I've also had two of them and highly recommend them. The first one
only
died because dropped it during servicing. All you need do is service
it
once a year by cleaning it and changing the media element, if
necessary.
I got two years out of each element.
Hmm. I wish.