On 1/6/2011 9:39 PM, The Daring Dufas wrote:
On 1/6/2011 7:05 PM, Tony Miklos wrote:
On 1/6/2011 8:25 AM, wrote:
On Jan 6, 1:28 am, The Daring
wrote:
On 1/5/2011 11:55 PM, Steve B wrote:





I just got a BIG combo oven and microwave from my daughter. She said
she
had not used the microwave for a year and a half, and my son in law
isn't
mechanically inclined, so they got a new one. Oven, MW combo and all.

I pulled the panels and looked for the obvious. The fuse was quite
corroded. I pulled it, polished the ends. It's a small Buss type fuse.
Cleaned the contacts, too. Reassembled.

Had to trim the door hooks a slight tad, too to get it to release
when you
push the release bar, but works like a charm now.

I have to put a plug on it tomorrow, and test, don't know if that
solved the
problem. Could the corroded fuse on the end have caused it to stop
conducting electricity? I did a continuity check on it using a 9v.
battery
and tester, and the reading was right at 9v., so I think the fuse is
good.

Just wondering. Don't know what got in there to cause the terminals
and
fuse ends to corrode. Hope it works tomorrow when I fire it up.

Steve

Corrosion kills a lot of electrical stuff and a bad connection can
cause
a terminal to heat up and burn up. This can also happen to a fuse
with a
bad connection. It will get hot and pop. Here's a link for some easy to
follow repair advice:

http://www.gallawa.com/microtech/index.html

As far as what caused the corrosion, it could have been caused by an
oven cleaner spray. I had to repair a commercial refrigeration unit
that a moron had used spray oven cleaner on to remove some built up
grime but some of the chemical got into the electrical control box
wreaking havoc with the wiring and power switch.

TDD- Hide quoted text -

- Show quoted text -

corrosion might have been caused by arcing at fuse. the contact
detoriates and heats blowing the fuse.

i would consider replacing the fuse holder if fuse blows again.

the machines i repair for a living do this a lot..


I had similar problems with the 1/4" glass fuses, mostly with 30amp
fuses. It happened almost from the time they were new. I'm sure someone
will tell me I'm reckless and dangerous but it always worked for me.
First a new fuse and fuse holder. Run it for 10 minutes. Unplug then
feel the fuse and holder. If it's hot or even a bit warm I installed a
second fuse holder parallel to it and installed 2 15 amp fuses in place
of the one 30 amp. The fuses and holders then stayed cool, and when the
bridge diode it powers goes bad, they blow and save the transformer. I
never had a call back on one of those mods.


Were you using the 1/4 inch Faston connectors to hook up the wiring?
In appliances, I'll always use the high temp nickel plated Fastons
for making connections. Not all slip on connectors are created equal.

TDD


The originals from the factory were standard Buss fuse holders rated at
30 amps, as were the ones I used to replace them with. At the time I
looked for higher rated fuse holders but couldn't find any. I had
measured the actual current but I don't recall what it was. It probably
would have worked from new if it wasn't turned on 12 to 24 hours a day.
I looked up Faston but I'm not sure of what you were referring to.