On Jan 5, 9:23*am, Matt wrote:
I'm planning to finish my basement and would like to take one side of
the stairwell wall and cut it down to a half-wall to open things up a
little. *Before I do this, I just want to make sure I'm not removing
bearing elements, or if I do, replace their load bearing capacity
somehow. *I've taken a few pics, linked below.

Pic Ahttp://img834.imageshack.us/i/15923046.jpg/*is just a photo
from the basement looking up the stairs. *The stairs turn left at the
landing and go up another 5 steps. *The bottom half of the stairs run
parallel with the joists, which are mostly TJI's. *The two TJI's i the
middle terminate at this cross-member, which is a 2x10. *To the side
of the TJI's and running directly above the stairwell walls are the
two 2x10's (or 2x12's...not sure). *They are a little darker in color
than the TJI's.

Pic Bhttp://img838.imageshack.us/i/90207730.jpg/is a look at the
stairwell from the basement. *The exposed studs there are the ones I
want to cut down to make that side of the stairwell a half wall.

Pic Chttp://img842.imageshack.us/i/42380765.jpg/is focused on the
2x10 that runs directly above the wall I want to remove. *I am
pointing to it.

Pic Dhttp://img547.imageshack.us/i/58100373.jpgis the junction of
the 2x10 and the cross member, showing that the cross member is hung
from those 2x10's with joist hangers. *The cross member appears
thicker than a 2x10, but on second thought, it's probably just because
it is drywalled on one side.

Pic Ehttp://img337.imageshack.us/i/52719782.jpg/is looking down the
stairs. *That rectangular piece at the top of the pic is the part I
was saying that someone really tall would bump their head on, and the
bottom 10" is formed by the cross member described above.

Pic Fhttp://img18.imageshack.us/i/98494464.jpg/is another shot of
the wall, showing what I want to do. *I basically want to make this a
half-wall to open up the stairwell into the basement to give it a more
open feeling. *I just want to make sure when I remove the top half or
so of those studs, I'm not removing bearing elements, or if I do, that
I properly replace their capacity somehow.

I will probably have a contractor come take a look, but I'd like some
thoughts from people *here as well


After looking at your pics, It doesn't seem that either wall is load
bearing by the look of the joists and the direction they are
traveling. Don't take my word for it though, if your still in doubt,
have a structural engineer come in and take a look to make sure. Sorry
i can't be any more help, but good luck with your renovation!