View Single Post
  #17   Report Post  
Posted to sci.electronics.repair
N_Cook N_Cook is offline
external usenet poster
 
Posts: 5,247
Default CD optical block shorting links

Arfa Daily wrote in message
...


"N_Cook" wrote in message
...
Mark Zacharias wrote in message
eb.com...
"Arfa Daily" wrote in message
...


"Mark Zacharias" wrote in message
eb.com...
"Arfa Daily" wrote in message
...


"Samuel M. Goldwasser" wrote in message
...
"N_Cook" writes:

Samuel M. Goldwasser wrote in message
...
"N_Cook" writes:





Hey, Geoff.

Actually there's been so few replaced by me in recent years, I don't
think
I've used a generic 240 yet. I've gotten "original Sony" pickups from a
reliable supplier, but none lately, so those "NOS" pickups may be gone.
I do believe that a lot of the "flaky KSS240" problems we experienced
over
the years were actually bad flat wires. Had one a couple months back.
Of course I can see where a generic might be shipped unadjusted and

that
could be disastrous. The are three adjustments on the 240 as you know,
not
just the laser power adjustment. Kind of hard to adjust them while they

are
playing!

Mark Z.



This generic Sanyo one , oriental script only, had the pot "set" at zero
ohms as well as zero ohms across the laser


That seems very odd. I don't think I've ever seen that. So, when you'd
removed the solder blob short, did it still not work ? Or was the pot

being
"set at zero ohms" equivalent to it running flat out ? Again, and odd
situation ... Did you reset it to some other value ? How ? Laser power
meter ?

Arfa


Pedants and purist look away now








I set the pot to the value of the original one and worked without hickup.
Then used the following , adjusting pot, which turned out to be centred as
far as I could tell by this method, to optimal as first set.

For checking error correction /immunity to errors.
An out of favour audio CD but otherwise in perfect playable condition.
With an assortment of potentiometer back nuts and washers ,small motor
pulleys find a combination that will "fill up" the hole in the centre of the
CD leaving
just a small hole at the very centre> With a set of "geometry" dividers
put one point
in this hole and lightly scratch a gouge about halfway along a radius of the
CD and about 1/4 of the circumference at that radius. Remove the washers
etc and play on a known good player.
Repeat the groove cutting deeper/wider/number of nearby grooves until one
track
or part of that track fails to play.
Make a note of the track number and start seconds and finish seconds
into the track/sections of track/s that are absent.
For your own machine every now and then (months) play and note the numbers
to note
long term drift. More absences/ longer absences over time indicates
deterioration in optics /correction . Use the same CD for checking in CD
repair of other machines and crude adjusting of optical power etc.