View Single Post
  #2   Report Post  
Posted to rec.crafts.metalworking
Ignoramus28169 Ignoramus28169 is offline
external usenet poster
 
Posts: 33
Default Electronic Kenmore refrigerator not working, what does thissign mean

On 2010-09-01, Jon Elson wrote:
On 08/31/2010 09:18 PM, Ignoramus20906 wrote:
Here are my findings:

1) The condenser fan is running fine
2) The compressor motor buzzes, then overload stops it, to restart in
a few minutes
3) The compressor motor is HOT
4) Inside of the relay does not look burned.

This could be the classic cascading hard-start. let the compressor
cool, it may just start right up and run fine. otherwise, you are on
the right track.


Jon, I will get replacement parts today (capacitor and relay) and will
try to use them, and will obviously start out with a cool compressor.

i