Default Recessing PVC Pipe Inside Interior Concrete Block Wall


"MiamiCuse" wrote in message
news
Between my Utility Room (Laundry and Ironing) and the Garage is a 4" thick
concrete block wall. I need to run a 2" PVC vent pipe up this wall and it
would save me a lot of trouble if I can recess the pipe into the wall.

This wall is NOT structural. In other words, the top of the wall is not
supporting anything on the roof, it is 8' tall and free standing. My
question is if I chisel out one side of a 4" thick concrete block wall
(which is really not 4" thick right?) will I be able to completely recess
a nominal 2" PVC fitting (not pipe, but the fitting which is larger in
diameter) into the cavity without breaking the other side of the face?

I know this is an obscured question, and if I have a 4" block laying
around I would just break one side of it and try it, but I don't have one
and thought if someone here might know.


Problems: A 4" block wall may be less than 4" thick, depending on the age of
the blocks as the manufacturers have resized them a couple of times over the
years. Also the cores in concrete blocks taper to allow the mould to be
extracted. A 4" concrete block core usually tapers down to nothing or just a
small gap at the top of the block, if it was laid correctly, so there is no
room for any sized pipe within the wall. Trying to pound out one side of a
concrete block wall only 4" thick will most likely cause the entire wall to
collapse.