Dave wrote:

"Pete C." wrote in message
ster.com...

Dave wrote:

We have some kind of clearish, gel-like stuff growing in our drip line,
and
I really don't think bleach is the best thing to be dumping in my yard.
Thinking if I just change the Ph a little for a while, like with vinegar
or
maybe even a couple pots of (cooled) tea, it might eliminate the problem.
What do others use?

To be fair, the guy who works on our unit says he uses bleach every
couple
months, but his drip line goes to the sewer and mine doesn't. My wife
mentioned the bleach idea to a building engineer where she works (40
story
block-wide building in downtown Houston) and he got really serious,
saying
don't ever put chlorine bleacn in anything like a drip line. It will eat
up
anything it comes in contact with. Now, I know that chlorine is highly
reactive, but is schedule 40 PVC really that fragile? If I had to I
could
catch the drip for a couple days...

Dave (who is uncertain at this point.)

Thanks


Yes, use *properly diluted* bleach to sanitize the condensate line from
your A/C evaporator / air handler unit. Use a pipe snake to clean the
built up gunk out of the line first. If your condensate line runs
outside and you are concerned about killing the grass, put a bucket
under the line when you do the sanitizer flush. Properly diluted bleach
sanitizer will definitely not harm PVC pipes.


Aah. Diluted bleach solution. That sounds more plausible. The A/C guy we
have been using just said to pour some bleach into where the line joins with
the condensor unit. Sooo... At what ratio should I dilute standard Clorox
bleach to get properly diluted bleach solution? Should I look for a
particular Ph?

Many, many thanks.

Dave


The dilution details are printed on the label of the bleach bottle. 3/4
cup bleach to 1 gal water is the strongest solution listed and is
certainly diluted enough not to harm PVC pipe or even a galvanized
condensate drip pan.