View Single Post
  #11   Report Post  
Posted to sci.electronics.repair
Sylvia Else[_2_] Sylvia Else[_2_] is offline
external usenet poster
 
Posts: 125
Default can i remove turns from shaded pole motor

On 25/06/2010 10:37 AM, PeterD wrote:
On Thu, 24 Jun 2010 23:04:00 +1000, Sylvia Else
wrote:

On 24/06/2010 9:46 PM, PeterD wrote:
On Thu, 24 Jun 2010 15:29:35 +1000, Sylvia Else
wrote:

On 24/06/2010 3:04 PM, Steve Sousa wrote:
Hello:

I live in a 230V area but need to use a 120V fan to repair an amplifier.
I can only get 230V fan motors here, so i was wondering if i can simply
remove turns from a 230v shaded pole motor to make it into a 120v one?

Thank you.



No. It's highly unlikely that the wire used in the motor is more than
100% overspecified, so if you remove turns from it to make it run at the
same speed on 120v, it will overheat, because the current will
approximately double.

Sylvia.

There is one high labor alternative that might work...

Take the current wire on the motor, and find the center, break it at
that point, so you have two 120 volt windings. Put in parallel for 120
volts, and series for 240 volts.

But, IMHO, hardly worth the effort, but technically feasible.


I'm not sure it's advisable either. There's every chance the enamel will
be damaged in the process. If he's lucky, any short will appear as soon
as he turns it on. If he's unlucky, it will occur when he's not looking.

Sylvia.


Advisable, probably not, but a theoritical solution, however!bg


That I agree with.

Sylvia.