View Single Post
  #22   Report Post  
Posted to rec.crafts.metalworking
Steve B[_10_] Steve B[_10_] is offline
external usenet poster
 
Posts: 3,055
Default Hobart handler 135 mig


Oil field pipe
welding for example...they generally fuse the bottom of the groove with
6010 for deep penetration of both pieces of pipe, and then finish with
7010 for a clean, neat finish bead that doesnt hang on stuff, is smooth
and penetrates all three surfaces..both pipes and the top of the 6010
bead.


I was on a lot of pipe jobs, and with the exception of the 54"OD 1/5" wall
that was done with an automated .072" FCAW and argon bug, it was ALL done
with 6010 or 6010 + on the root, and 7018 on the rest. This would be for
pipeline carrying crude and gas from offshore pipelines to onshore
refineries. I do not recall ever seeing a 7010 offshore. With a couple of
rare exceptions, it was 6010 and 7018.

Steve

visit my blog at http://cabgbypasssurgery.com watch for the book

A fool shows his annoyance at once, but a prudent man overlooks an insult.