It's not clear from this, but do ensure that you never run mutiple
romex cables through a knockout on the subpanel. Once cable (with
appropriate clamp) per knockout.
As long as the clamp is rated for two cables, where's the problem?
Shouldn't be a problem. They're not very common.
More common than you think. Take a look at the fine print on the next package
you buy; you might be surprised. It's been quite a while since I've bought any
romex clamps that were *not* rated for two 12-2 or 14-2 cables.