View Single Post
  #17   Report Post  
Posted to sci.electronics.repair
Phil Allison[_2_] Phil Allison[_2_] is offline
external usenet poster
 
Posts: 1,716
Default PAT testing. Anyone else think that sometimes, it causes damage ?


"Mark Allread"

I had to look up "PAT Testing" online. It sounds like yet one more
unnecessary time-and-money-wasting government annoyance, like lead-free
solder and banned cleaning solvents. I'm sure we in the USA will be doing
that too, soon enough. At first glance, an incorrectly applied PAT sounds
like a fine way to destroy MOV protection devices.



** MOVs are NOT connected from line to ground inside equipment sold in
Europe or Australia - cos it is a very dangerous practice.

In any case, the appliance tester only outputs a very small current to the
device under test in order to measure leakage to frame or chassis and is not
normally applied across the AC line terminals.


..... Phil