View Single Post
  #7   Report Post  
Posted to uk.d-i-y
rog[_2_] rog[_2_] is offline
external usenet poster
 
Posts: 17
Default Hilti bolt spacing

On 4 June, 21:17, Tim Watts wrote:
On 04/06/10 21:15, Davao - Arthur55 wrote:





*wrote in message
....
Hi I'm putting a new floor level in an old concrete block building. I
am intending to hilti bolt a 3 x 6 wooden beam on opposing walls then
using joist hangers on them joisting across ( 14ft 1in span, 18inch
spacing ) with 6x2 joists.
Any suggestions on dimensions and spacing of the hilti bolts, also am
going to double up joists where bath& *water cylinder etc will be; is
it normal to have double width hangers for this or just bolt together
timbers?
I'm stuck with max 6in depth of joists as stuck for internal room
height.


None of the above advisors answered your question on the hilti bolts.
I'd be interested in the answer to this particular qustion.


Good luck.


Arthur


One did - he said 200mm in from the and every 450mm (or joist spacing).
I think he also said "use resin bolts" which is what I would do too,
especially for something like this.

--
Tim Watts

Hung parliament? Rather have a hanged parliament.


Thanks for the info
Roger