View Single Post
  #34   Report Post  
Posted to alt.home.repair
RBM[_3_] RBM[_3_] is offline
external usenet poster
 
Posts: 1,473
Default Troubleshooting well pump ( with pics)


"Mikepier" wrote in message
...
OK here is another test I did. I have a Wayne portable pump. It is
self priming, and hose bibs for the inlet and outlet. I stuck a 10
foot house down the well and sucked all the water out. The water did
not return to it's steady state level until about 3-4 minutes later.
Does this imply the screen is clogged , or there is a problem with the
well? It seems there should be a steady supply of water if I'm sucking
it out with my portable pump.



That pretty much demonstrates that the foot valve is stuck, practically
closed or clogged. Filling the pipe with water and seeing it slowly drain
out shows the same thing