Thread
:
Air Compressor Problem - Motor Stalls
View Single Post
#
55
Posted to sci.electronics.repair
Jeffrey D Angus[_2_]
external usenet poster
Posts: 69
Air Compressor Problem - Motor Stalls
lid (Sparks Fergusson) wrote:
...
The voltage to the motor is never interrupted during the stop/start
cycle. Above a certain psi (about 95), the motor starts bogging down
and eventually stops. This occurs even if I bypass the pressure switch
and attach the cord directly to the motor leads. Then, after the
unloader vents the pressure, the motor will restart.
Is it an oil-less compresser? They are VERY sensitive to
both ends being lined up correctly. The through bolts loosen
under vibration and the ends shift slightly. Re-align them
and that should solve the problem.
Jeff
--
“Egotism is the anesthetic that dulls the pain of stupidity.”
Frank Leahy, Head coach, Notre Dame 1941-1954
http://www.stay-connect.com
Reply With Quote
Jeffrey D Angus[_2_]
View Public Profile
Find all posts by Jeffrey D Angus[_2_]