On Thu, 28 Jan 2010 16:36:08 -0000, "Toby"
wrote:

Turn of the valves (Count the turns on the lock shield and write it down
somewhere!)
Open the bleed screw to relese any pressure, but then close the bleed screw
(you shouldn't get very much water out, if any).
put old towels around the valves and then undo the nuts about half a turn.
lift the radiator off the wall brachet and then hinge it down so the top is
now on the floor.
Do up the nuts.


I remember someone had the idea of a fitting that screwed on to the
wall behind the rad and another to the rad and both were connected by
a chain so you loosened the nuts and pulled it forward and it was held
by the chain.....don't think it ever took off tho'